Changes in P1 latencies of children with normal hearing and those with cochlear implants

Authors: EMRE ESKİCİOĞLU, GÜNAY KIRKIM, SELHAN GÜRKAN, SERPİL MUNGAN DURANKAYA, TAHSİN OĞUZ BAŞOKÇU, ENİS ALPİN GÜNERİ

Abstract: Background/aim: The aim of this study was to determine the age-related latency interval of P1 latencies of children with normal hearing, and to evaluate the P1 latency changes after surgery in children who underwent cochlear implantation. Materials and methods: We evaluated 60 children with normal hearing and 16 children with cochlear implants aged 0-6 years using cortical auditory evoked potentials. P1 latencies were measured only once in the children with normal hearing, and on the postoperative first day, and the first, third, and sixth postoperative months in the children with cochlear implants. Results: There was a statistically significant decrease in the P1 latencies as the age increased in children with normal hearing (P < 0.001). It was determined that when the external partof the cochlear implant was applied, the P1 latencies of children with cochlear implants were significantly longer than those of age-matched children with normal hearing (P < 0.001). This difference disappeared in 10 children with implants at the third and sixth months, but significant differences remained in 6 children. Conclusion: P1 latency could be used as an objective tool to evaluate the normal development of auditory pathways, and may be helpful in the effective programming of children undergoing cochlear implantation.

Keywords: Cortical auditory evoked potentials, cochlear implantation, P1 latency, children, normal hearing

Full Text: PDF